Building permit at 3306 19TH ST NW, WASHINGTON, DC 20010
Work description
In the Mount Pleasant Historic District The inspector failed my completed wall on 10/6/25 because he read the drawings to specify horizontal rebar in the side wall. The engineer said the inspector misinterpreted the plans. He has revised the drawings to clarify that no horizontal rebar was needed, only truss mesh. He has also revised the wall height to 4' and revised the railing details to allow wood or vinyl. The engineer has also written a letter explaining these changes and stating that the wall was constructed correctly.
Property history
| Issued | Address | Work description | Est. value | |
|---|---|---|---|---|
| 2026-08-24 | 3306 19TH ST NW, WASHINGTON, DC 20010 | — | › |
Public record from DC Open Data (Dept. of Buildings). Owner name and contact details are not part of this open-data feed unless shown above. Verify details before use.